pxie-5163. The NI PXIe-5163 PXI Oscilloscope utilizes a maximum bandwidth of 200 MHz. pxie-5163

 
 The NI PXIe-5163 PXI Oscilloscope utilizes a maximum bandwidth of 200 MHzpxie-5163  14

PXIe-5163 SMB PFI 02 PXIe-5164 SMB PFI 02 1 Requires a probe capable of compensating high capacitance inputs and a BNC (f)-to-SMB (f) cable with sufficiently low capacitance, such as the 0. NI-SCOPE Support from Instrument Control Toolbox Control and acquire data from NI-SCOPE devicesEDIT: OK if you want to suppress errors from failing asserts don't do a try/except in every place you need it. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that facilitates high-speed data throughput and. Pxie-5163 Mini-HDMI Breakout Cable to 6 BNC Pinout. 14. The IVI driver can also be used with the NI-FGEN support package in MATLAB ® releases R2022a and earlier. For this calculation, we’ll use a 1-MΩ internal. Added support for exporting instrument events to PXI chassis trigger lines. PXIe-5172*. PXIe-5162 is a 1. Touch any metal part of the chassis to discharge static electricity. Y 1: PXIe-5185. And have this call your assert, so it will run the code. PXIe-5163 là mô-đun máy hiện sóng tốc độ cao, có 2 hoặc 4 kênh lấy mẫu ở tốc độ lên đến 1 GS/s, cung cấp các tính năng cài đặt linh hoạt và có thể lập trình cho bộ ghép nối đầu vào, trở kháng ngõ vào, dải điện áp và lọc. Running Self-Calibration. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。NI SP500C Oscilloscope Probe. This IVI driver can be used with the IVI and VXI plug&play support package in R2022b and later. The PXIe-5163 is an oscilloscope created by National Instruments. 13. 6. 14. Configuring the Pxie-5163 in MAX. 12. PDF. 3. Configuring the Pxie-5163 in MAX. Pxie-5163 Mini-HDMI Breakout Cable to 6 BNC Pinout. If problems persist, then contact NI Support . 13. 2D Dimensional Drawings PDF DXF 3D CAD Models PRT STP IGS Product. Scope Model PXIe-5160 PXIe-5162 PXIe-5110 PXIe-5111 PXIe-5113 PXIe-5774 Oscilloscope 50Ω Path Bandwidth 500 MHz 1. 8. Making a Measurement with Instrumentstudio. Pxie-5163 Mini-HDMI Breakout Cable to 6 BNC Pinout. Making a Measurement with Instrumentstudio. Pxie-5163 SCB-19 Pinout. First Measurements. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。This example shows how to acquire digital waveforms from two channels of a National Instruments® NI-SCOPE driver in the simulation mode and display the waveforms in MATLAB®. Documentation for the PXIe-5163 is available from the Start menu by navigating to NI-SCOPE Documentation in the National Instruments folder. Page 3: Verifying The System Requirements PXIe-5163; PXIe-5698; Calibration Executive 6. Added support for arbitrary waveform generation mode to the Waveform Generator panels. Pxie, 200 mhz, 1 gs/s, 14-bit pxi oscilloscope (22 pages)Pxie-5163 Front Panel and Pinout. If you are using the NI-SCOPE . Farnell Lietuva pateikia greituosius pasiūlymus, išsiuntimas tą pačią dieną, greitas pristatymas, didelės prekių atsargos, duomenų lapai ir techninė pagalba. NI-SCOPE for Linux/x86 64-bit Architecture Readme. Yes. 14. com Solution. Added support for exporting instrument events to PXI chassis trigger lines. 5 V 5 V Table 1. The CC3050X (Part Number: 785562-01) is a clamp-on, wide bandwidth current Oscilloscope Probe that offers 30A of continuous input DC to 50 MHz bandwidth. 11. ni‑scope 18. Pxie-5163 Front Panel and Pinout. Test Equipment National Instruments PXIe-5163 Getting Started Manual. NET Framework 4. Before you begin, install and configure your chassis and controller. 14. 5 ghz, 2. 18 Integrated from 100 Hz to 10 MHz. First Measurements. The PXIe-5162 high-speed oscilloscope device has two or four channels that sample at up to 5 GS/s with flexible settings for coupling, voltage range, and filtering. 785182-01. This page provides dimensional drawings for the PXIe-5163. The problem is that we are quit new with Labview fpga code and we are facing some problems to find examples. The. NET programming. 7. Ensure that the ejector handle is in the downward (unlatched) position. Configuring the Pxie-5163 in MAX. Brand: National. Page 1: Table Of Contents. 5 baths property. Documentation for the PXIe-5163 is available from the Start menu by navigating toBuy 785182-01 - Ni - PXIE-5163 PXI OSCILLOSCOPE, 200 MHZ, 14 BITS, 1 GS/S, 2 CHANNELS, 512 MB ROHS COMPLIANT: YES. Y: PXIe-5170-PXIe-5171-PXIe-5172. 12. PXI Express Peripheral Slot 3. 8. 3. 7 adds support for CableSense to the PXIe‑5110, PXIe‑5111, PXIe‑5113, PXIe‑5160, and PXIe‑5162 oscilloscopes. This document explains how to install, configure, and test the PXIe-5163. Pxie-5163 SCB-19 Pinout. Acquires and analyzes time- and frequency‐domain analog signals as part of a PXI system. 5 GHz 5 GS/s 10 bits, 2/4 channels 14-Bit Scopes: Optimized for Resolution and Density PXIe-5122 100 MHz 100 MS/s 2 channels. Y: PXI-5922. Configuring the Pxie-5163 in MAX. Find used oscilloscopes on Machinio. 7. PXIe-5163; PXIe-5698; Calibration Executive 6. 15. 1 Mb 38. This Oscilloscope Probe is designed for precise current measurements and can be attached to a variety of oscilloscopes. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. The PXIe-5163 is a 200 MHz, 1 GS/s oscilloscope. 7. Configuring the Pxie-5163 in MAX. This document explains how to install, configure, and test the PXIe-4163. SPECIFICATIONS PXIe-5163 PXIe, 200 MHz, 1 GS/s, 14-bit PXI Oscilloscope Contents Definitions. 7. 08 m SMB-100 (part number 781449-01). PXIe-5163 Specifications. Note. The PXIe-5423 ships with NI-FGEN driver software, which you can use to program the module. Running Self-Calibration. Pxie-5163 Self-Calibration. Microsoft Visual Studio Support. This home was built in 1986 and last sold. The PXIe-5163 PXI Oscilloscope is manufactured with a maximum sample rate of 1 GS/s. Making a Measurement with Instrumentstudio. 7. Running Self-Calibration. 5163 Santa Clara Ave, Victoria, BC V8Y 1W5 is currently not for sale. Get support on a product. Pxie-5163 Front Panel and Pinout. Microsoft Visual Studio Support. Find used oscilloscopes on Machinio. National Instruments manufactures the PXIe-5163 PXI Oscilloscope. Hioki current probes may require short BNC adapters when used with closely adjacent oscilloscope channels. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data. 13. Documentation for the PXIe-5163 is available from the Start menu by navigating toNI‑SCOPE 18. Making a Measurement with Instrumentstudio. Running Self-Calibration. 5 GHz, 10-bit oscilloscope with a sample rate of up to 5 GS/s. Documentation for the PXIe-5163 is available from the Start menu by navigating toSPECIFICATIONS PXIe-5163 PXIe, 200 MHz, 1 GS/s, 14-bit PXI Oscilloscope Contents Definitions. 13. 0 (minimum) is required. 12. Used National Instruments oscilloscopes for sale in North Carolina, USA. Product support: FD-11613; FD-11614; NI 9210; NI TB-9212 with mini-TC; PXIe-4135 (40W) PXIe-4137 (40W) Calibration Executive 6. Pxie-5163 Self-Calibration. This documents provides information on calibration service levels available for NI Products. 5 GHz, 10-bit oscilloscope with a sample rate of up to 5 GS/s. The NI SA1000X probe is associated with the family of SA probes by National Instruments. 15. First Measurements. 5 GS/s 2 channels 10-Bit and 12-Bit Scopes: Optimized for Speed, Resolution, and Density PXIe-5105 60 MHz 60 MS/s 12 bits, 8 channels PXIe-5160 500 MHz 2. Y: PXIe-5170-PXIe-5171-PXIe-5172. 0 (minimum) is required. Pxie-5163 SCB-19 Pinout. This document explains how to install, configure, and test the PXIe-5164. 5 ghz, 2. crossrulz. 14. 13. Y 1 Requires SMB to BNC adapter. 1 When you install NI-SCOPE on a 64-bit installation of Windows, InstrumentStudio is installed instead of the SCOPE soft front panel. Pxie-5163 Self-Calibration. Y 1: PXIe-5185. Oscilloscopio PXI a 14 bit, 1 GS/s 200 MHz, PXIe. NI‑SCOPE 18. 5 GHz 100 MHz 350. PXIe/PXI/PCI-5105 PXI/PCI-5152 PXIe-5160 PXIe-5162 PXIe-5163 PXIe-5164 Oscilloscope Probe Compensator 1. Single-channel sweep mode support for PXIe-4190 when used in LCR mode. Measure the internal device temperature and perform self. Brand: National. Achieving accurate low-power validation Article By : David Hall, Macarena Calderon, Mike Denton and Paul UlezkoThe PXIe-5164 is a single-slot module with one backplane connector. This process varies from computer to computer and is often not a trivial process. PXI Oscilloscopes also feature a number of triggering. Pxie-5163 Mini-HDMI Breakout Cable to 6 BNC Pinout. Pxie-5163 Mini-HDMI Breakout Cable to 6 BNC Pinout. 6 Vpk-pk. comSolution. 11. Pxie, 400 mhz, 1 gs/s, 14-bit pxi oscilloscope (24 pages) I/O Systems National Instruments NI 9485 Getting Started Manual. 以下では、PXIe-5164再構成可能オシロスコープの特長、ならびに、これらの特長がテストのコスト削減、市場投入までの時間短縮、テスト歩留まりの向上にどのように貢献するかを説明します。. 7 Readme. Duty cycle tolerance. In the project, you should be able to right-click on the FPGA Target and add IO. 14. Added CSV file format for data capture. Page 8 5. If you are using the NI-SCOPE . 13. NI-SWITCH Support from Instrument Control Toolbox. Calibration IP is used properly when using LabVIEW Instrument Design Libraries for Reconfigurable Oscilloscopes (instrument design libraries) to create FPGA bitfiles. 14. Y: PXIe-5164. Configure the PXIe-4139 to voltage output mode and enable remote sensing. PDF. 15163, PXIe-5164, PXIe-5170, USBUSB-5132, USB-5133 Simulation PWM (Pulse Width Modulation) Controller Instruments Supported NI DAQmx Generic DAQmx PXI, C Series, CompactDAQ supporting CO Pulse Freq Simulation Phase Noise Analyzer Instruments Supported Holzworth_HA7000 HA7062C, HA7062D. This IVI driver is for use with NI oscilloscopes. 14. PXIe, 200 MHz, 1 GS/s, 14-bit PXI Oscilloscope. 8. pdf. pxie 5110 5111 5113 getting started guide. 2 Though the PFI 0 line is also available via the AUX 0 MHDMR connector, thePXIe-5163 SMB PFI 02 PXIe-5164 SMB PFI 02 1 Requires a probe capable of compensating high capacitance inputs and a BNC (f)-to-SMB (f) cable with sufficiently low capacitance, such as the 0. Documentation for the PXIe-5163 is available from the Start menu by navigating to The PXIe‑5163 high-resolution oscilloscope has two channels that sample at up to 1 GS/s with flexible and programmable settings for coupling, input impedance, voltage range, and filtering. 7 adds support for the PXIe‑5163 oscilloscope. NET Framework 4. 14. NI-VISA. NET in any. Excludes trigger jitter. The PXIe-4163 ships with NI-DCPower driver software, which you can use to program the module. 5163 Rocky Point Rd is a 1,008 square foot house on a 3 acre lot with 1 bedroom and 1 bathroom. The NI PXIe-5163 is capable of triggering signals with multiple modes. The PXIe‑5163 high-resolution oscilloscope has two channels that sample at up to 1 GS/s with flexible and programmable settings for coupling, input impedance, voltage range, and filtering. PDF. 1で修正さ. NI Oscilloscope PXIe-5105 PXIe-5110 PXIe-5111 PXIe-5113 PXIe-5114 PXIe-5122 PXIe-5160 PXIe-5162 PXIe-5163 PXIe-5164 PXIe-5170 PXIe-5171 PXIe-5172 PXI-5922 Scope Connector SMB BNC BNC BNC BNC BNC BNC BNC BNC BNC SMA SMA SMB BNC Single Ended Passive Probe SP400x Y Y Y - - Y Y Y Y - - Y SP500c Y Y Y - - Y Y Y Y - - Y CP500x Y Y Y - - Y Y Y Y - - Y NI-SWITCH Support from Instrument Control Toolbox. PXIe-5170* 100 MHz . 14. Making a Measurement with NI-SCOPE SFP. NI-SCOPE 18. Hioki current probes may require short BNC adapters when used with closely adjacent oscilloscope channels. 2 Though the PFI 0 line is also available via the AUX 0 MHDMR connector, theFigure 2. The NI SA1000X is launched with the part number 784255-01. Added support for exporting instrument events to PXI chassis trigger lines. You are browsing the LATIN_EN site. 8. The PXIe‑5163 high-resolution oscilloscope has two channels that sample at up to 1 GS/s with flexible and programmable settings for coupling, input impedance, voltage range, and filtering. Pxie-5163 Self-Calibration. To access PXI/PXIe/PCI-5122 documentation, including the NI PXI/PXIe/PCI-5122 Getting Started Guide, go to Start»All Programs»National Instruments»NI-SCOPE» Documentation. Added support for exporting instrument events to PXI chassis trigger lines. This module features 4-quadrant operation, integrated remote (4 wire). NI-DAQmx. Test Equipment National Instruments PXIe-5163 Getting Started Manual. The PXIe-5164 (Part Number: 784183-01) High-speed Oscilloscope by National Instruments is perfect for applications with quick signals requiring up to 400 MHz of simple transfer speed and adaptable estimation setups for up to 250 V. 5 V 1 V 2. The NI-SCOPE . View online (18 pages) or download PDF (957 KB) National Instruments PXIe-5163, PXIe-5162 User manual • PXIe-5163, PXIe-5162 software PDF manual download and more National Instruments online manualsPXIe-5160 Bandwidth-Limiting Filters Frequency Response, 1 Vpk-pk, Measured 1 –11 –10 –9 –8 –7 –6 –5 –4 –3 –2 –1 0 Frequency (Hz) 10 M 100 M ed Amplitude (dB) Spectral Characteristics 50 Ω Spectral Characteristics Table 7. Yes. Y 1: PXIe-5185. "-Mike Phan "Hand carrying parts to fedex directly to make sure I get them overnight. 13. Ensure you are powering them up in the right order - chassis, wait a few seconds, then computer. . PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data. 14. 13. 7 adds support for variable rate external sample clocks to the PXIe‑5170 and PXIe‑5171 reconfigurable oscilloscopes. This document explains how to install, configure, and test the PXIe-5163. The PXIe-5163 is built with 50 Ohm, 1 MOhm input impedance. National Instruments PCI-5122, PXIE-5160, PXIE-5162, and PXIE-5622 oscilloscopes for sale. 6 GHz NI 5663E Band 2 IMD3 NI 5663E Band 3 IMD3Pxie-5163 Front Panel and Pinout. 7. If you are using the NI-SCOPE . Maximize Accuracy and Input Range. 14. PXIe-5164* 400 MHz . 0でサポートされているハードウェアモデルは、次の表のとおりです。これらのモジュールのデバイス固有の情報は、『NI 高速デジタイザヘルプ』に記載されています。 既知の問題. First Measurements. 250 MS/s, 14-Bit Reconfigurable Oscilloscope. 14. Making a Measurement with Instrumentstudio. You can use MATLAB together with Instrument Control Toolbox as your single software environment to configure, control, acquire, and analyze data from these instruments. PXIe-5172で、新たに帯域幅制限フィルタ (80 MHz、40 MHz) およびオンボードクロックレート (200 MS/s、150 MS/s) がサポートされました。 サポートされているハードウェア. Yes. • Keep cabling as short as possible. 7. The NI PXIe-5164 comes equipped with a client programmable FPGA, synchronization aptitudes, and data composing. 8. Running Self-Calibration. 11. The PXIe-5163 is a 200 MHz, 1 GS/s oscilloscope. 08 m SMB-100 (part number 781449-01). Pxie-5163 SCB-19 Pinout. NI-TClk is an API that enables system synchronization of supported PXI modules in one or more PXI chassis, which you can use with the PXIe-5163 and NI-SCOPE. 2. 11. Ensure that the load impedance matches the output impedance specified in the Programmable Function Interface table in the respective specifications sheets: PXIe-5160 Specifications. 5 V 1 V 2. 1 No support for the PXIe-5110/5111/5113, the PXIe-5163, or the PXIe-5164 and PXIe-517x reconfigurable oscilloscopes. 08 m SMB-100 (part number 781449-01). PXIe-5163 PXIe, 200 MHz, 1 GS/s, 14-bit PXI Oscilloscope Note Before you begin, install and configure your chassis and controller. Hioki current probes may require short BNC adapters when used with closely adjacent oscilloscope channels. PXIe-5163 / 785182-01 - NI (National Instruments) PXIe, 200 MHz, 1 GS/s, 14-Bit PXI Oscilloscope—The PXIe‑5163 high-resolution oscilloscope has two channels that sample at up to 1 GS/s with flexible and programmable settings for coupling, input impedance, voltage range, and filtering. NET Framework 4. Pxie-5163 Self-Calibration. pdf. PXIe-5163 PXIe, 200 MHz, 1 GS/s, 14-bit PXI Oscilloscope Note Before you begin, install and configure your chassis and controller. Y: PXIe-5186. 14. 1 No support for the PXIe-5110/5111/5113, the PXIe-5163, or the PXIe-5164 and PXIe-517x reconfigurable oscilloscopes. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. PXI Express Chassis PXIe-1092 or PXIe-1095 If these chassis are unavailable, use a PXI Express Chassis with ≥ 58 W slot cooling capacity. 0 GHz Band 3 = 3. Running Self-Calibration. 14. Discover the NI VirtualBench All-in-One Instrument. Ensure that the load impedance matches the output impedance specified in the Programmable Function Interface table in the respective specifications sheets: PXIe-5160 Specifications. All baud rates are supported because the UART can get w ithin 1. 1 No support for the PXIe-5110/5111/5113, the PXIe-5163, or the PXIe-5164 and PXIe-517x reconfigurable oscilloscopes. Added access and visibility to pin maps; Improved UI responsiveness and added pin filtering for systems with high channel counts. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that facilitates high-speed data throughput and. 13. 13. 1 GS/s . 98 dBm Input Signal at Connector, 50 Ω, 1 V. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that facilitates high-speed data throughput and. 14. 11. The PXIe-5163 is a 200 MHz, 1 GS/s oscilloscope. This model. 14. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Pxie-5163 SCB-19 Pinout. Pxie-5163 Front Panel and Pinout. Pxie-5163 Front Panel and Pinout. Making a Measurement with NI-SCOPE SFP. 12. Running Self-Calibration. 14. There are a couple of options to resolve this issue: Disable ECRC on the host. It accepts PXI Express modules in every slot and supports standard PXI hybrid-compatible modules in. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that facilitates high-speed data throughput and. 6 adds support for the PXIe‑5110, PXIe‑5111, and PXIe‑5113 oscilloscopes. NET Class Library can be used with Visual C# or Visual Basic . Y: PXIe-5164. SA2500X USER GUIDE. This page provides dimensional drawings for the PXIe-5163. The PXIe-4163 is a single-slot module with one backplane connector. 6. Y: PXIe-5186. PXIe-5172で、新たに帯域幅制限フィルタ (80 MHz、40 MHz) およびオンボードクロックレート (200 MS/s、150 MS/s) がサポートされました。 サポートされているハードウェアPXIe-5163 PXIe, 200 MHz, 1 GS/s, 14-bit PXI Oscilloscope Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. PXIe-5164. 5 GHz, 5 GS/s, 10-Bit PXI Oscilloscope. 0 –100 –90 –80 –70 3 No support for the PXIe-5110/5111/5113, the PXIe-5163, or the PXIe-5164 and PXIe-517x reconfigurable oscilloscopes. Figure 14. Programming the Pxi/Pxie/Pci-5122. Configuring the Pxie-5163 in MAX. PXIe, 1. 14. 13. 9. 14. The user can also order the NI PXIe-5163 by using the part number 785182-01. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。This device is ideal for automated and partially automated time- and frequency-domain applications that require high-resolution, low-noise measurements with up to 200 MHz of analog bandwidth and up to 250 V. 0 (minimum) is required. It belongs to the PXI Oscilloscope series and can be identified with the part number 785182-01. 3. PXIe-5163 Dimensional Drawings This page provides dimensional drawings for the PXIe-5163. PXIe-5186 5 GHz 12. 5 GHz, 5 GS/s, 10-Bit PXI Oscilloscope. Custom gating support for Scope measurements. Test Equipment National Instruments PXIe-5163 Getting Started Manual. This document explains how to install,. Pxie, 400 mhz, 1 gs/s, 14-bit pxi oscilloscope (24 pages)PXIe-5163 寸法図Order today, ships today. SPECIFICATIONS PXIe-4163 PXIe, 24-Channel, ±24 V, 50 mA Precision PXI Source Measure Unit Definitions Warranted specifications describe the performance of a model. NI PXIe-5163 ; NI Categories. NI-TClk is an API that enables system synchronization of supported PXI modules in one or more PXI chassis, which you can use with the PXIe-5163 and NI. Making a Measurement with Instrumentstudio. PXIE 5164 GETTING STARTED GUIDE. This passive Oscilloscope Probe can work over a wide voltage range of -300 to +300 V. 2 channels. 5 GS/s 10 bits, 2/4 channels PXIe-5162 1. Configuring the Pxie-5163 in MAX. 13. 2 Though the PFI 0 line is also available via the AUX 0 MHDMR connector, theTest Equipment NI PXIe-5163 Calibration Procedure (48 pages) Test Equipment NI FDT-16040 Safety, Environmental, And Regulatory Information. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。Test Equipment NI PXIe-5163 Calibration Procedure (48 pages) Test Equipment NI PXI-5122 Getting Started Manual. NI 9212 NI-XNET CAN HS cRIO-9031 cRIO-9425 with DSUB PXIe-2737 cRIO-9472 NI PXI-1033 NI PXI-1031 cRIO-9065 PXIe-1062 NI 9247 NI 9145 NI 9207, NI 9208, NI 9209 with DSUB, NI 9210 with mini TC, NI 9775 cFP-CAL NI 9228 ($) cDAQ-9185 cRIO-9042 PXIe-1084 cRIO-9056 NI PXIe-5163 PXIe-5110 cRIO-9208 w. Test Equipment National Instruments PXIe-5163 Getting Started Manual. The capabilities listed in this document represent capabilities available at National Instrument and Certified Calibration Center labs. 12. 7 adds support for variable rate external sample clocks to the PXIe‑5170 and PXIe‑5171 reconfigurable oscilloscopes. Figure 14. Control and acquire data from NI-SCOPE devices. 13. Documentation for the PXIe-5160/5162 is available from the Start menu by navigating to. Refer to ni. NET Framework 4. PXIe, 200 MHz, 1 GS/s, 14-Bit PXI Oscilloscope. Pxie-5163 Front Panel and Pinout. Control Unit I/O Systems Controller Measuring Instruments Chassis. 12. Y 1 Requires SMB to BNC adapter. 14. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The capabilities listed in this document represent capabilities available at National Instrument and Certified Calibration Center labs. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that facilitates high-speed data throughput and.